Reference standard: EN 13924-2:2014
| Property |
Unit |
Method |
PARAFALT (VMT 45) |
PARAFALT (VMT 65) |
| Penetration at 25°C |
0,1 mm |
EN 1426
|
35 - 50 |
50 - 70 |
| Softening Point R&B |
ºC |
EN 1427
|
59 - 69 |
54 - 64 |
| Retained penetration after RTFOT |
% |
EN 12607-1 EN 12593
|
≥ 60 |
≥ 60 |
| Increase of Softening Point R&B after RTFOT |
°C |
EN 12607-1 EN 1426
|
≤ 10 |
≤ 10 |
| Penetration Index |
°C |
EN 12607-1 EN 1427
|
< 0,5
|
< 0,5
|
| Solubility |
% |
EN ISO 12592
|
≥ 99,0 |
≥ 99,0 |
| Flash point, COC |
°C |
EN ISO 2592
|
≥ 260 |
≥ 250 |
| Fraass breaking point |
°C, max. |
|
NR |
NR |